MTCB-500kW-1000kWh
MTCB-500kW-1000kWh
ALL-IN-ONE Container Energy Storage System
- Integrated Power Control, Energy Management & Battery Management Systems
- Support PV, BAT, DG and GRID access
- Automatic switching between on/off-grid
- Support forklift and hoisting transportation
- Event and Caution Alarm
- Real time and History Data Accumulation
- Dual Working Power Support
INQUIRY FORM:
More About MTCB-500kW-1000kWh
Category
Parameter
Value
DC Data
Cell Type
Prismatic LFP
Cell Brand
HiGEE
Cell Life Cycle
>8,000 [email protected],25°C
Cell Spec
3.2V/280Ah
String Configuration
1P224S
Number of Strings
5
String Rated Energy Capacity
200kWh
DC Rated Energy Capacity
1000kWh
Rated Voltage
716.8V
Voltage Range
628V~806V
BMS Communication Interface
Ethernet, CAN, RS485
BMS Communication Protocol
Modbus RTU, Modbus TCP
AC Data
Rated AC Power
500kW
Maximum AC Power
550kW
Rated AC Voltage
400V
AC PF
1 leading ~ 1 lagging
Output THDi
≤3%
Nominal Grid Frequency
50/60Hz (To be set)
Isolation Method
3 Phase 4 Line Transformer
General Data
Dimension w/o Clearances (L*W*H)
6,058*2,438*2,591mm
Weight of Whole System
<30M T
Degree of Protection
IP65
Operating Temperature Range
-20~65°C
Relative Humidity
0~95% (non-condensing)
Max Working Altitude
3,000m/9,842ft
Cooling Concept of DC Hatch
HAVC
Cooling Concept of PCS Hatch
Forced air cooling
Fire Extinguisher System
HFC bottle group
Communication Interfaces
RS485, Ethernet, GPRS
Communication Protocols
Modbus RTU, Modbus TCP
Category | Parameter | Value |
---|---|---|
DC Data | Cell Type | Prismatic LFP |
Cell Brand | HiGEE | |
Cell Life Cycle | >8,000 [email protected],25°C | |
Cell Spec | 3.2V/280Ah | |
String Configuration | 1P224S | |
Number of Strings | 5 | |
String Rated Energy Capacity | 200kWh | |
DC Rated Energy Capacity | 1000kWh | |
Rated Voltage | 716.8V | |
Voltage Range | 628V~806V | |
BMS Communication Interface | Ethernet, CAN, RS485 | |
BMS Communication Protocol | Modbus RTU, Modbus TCP | |
AC Data | Rated AC Power | 500kW |
Maximum AC Power | 550kW | |
Rated AC Voltage | 400V | |
AC PF | 1 leading ~ 1 lagging | |
Output THDi | ≤3% | |
Nominal Grid Frequency | 50/60Hz (To be set) | |
Isolation Method | 3 Phase 4 Line Transformer | |
General Data | Dimension w/o Clearances (L*W*H) | 6,058*2,438*2,591mm |
Weight of Whole System | <30M T | |
Degree of Protection | IP65 | |
Operating Temperature Range | -20~65°C | |
Relative Humidity | 0~95% (non-condensing) | |
Max Working Altitude | 3,000m/9,842ft | |
Cooling Concept of DC Hatch | HAVC | |
Cooling Concept of PCS Hatch | Forced air cooling | |
Fire Extinguisher System | HFC bottle group | |
Communication Interfaces | RS485, Ethernet, GPRS | |
Communication Protocols | Modbus RTU, Modbus TCP |